HQT-4160 Tested & Approved Hitachi Vantara Qualified Professional Study Materials
Validate your Skills with Updated Hitachi Vantara Qualified Professional Exam Questions & Answers and Test Engine
NEW QUESTION # 18
What is a critical step in the pre-installation checklist for ensuring the physical security of the VSP
5000 system?
- A. Configuring firewall settings
- B. Securing the racks to the floor
- C. Installing surveillance cameras in the data center
- D. Setting BIOS passwords
Answer: B
Explanation:
The Hitachi VSP 5000 is a large enterprise storage system typically installed in data center racks.
A key pre-installation physical security and safety requirement is ensuring that racks are properly anchored or secured to the floor.
This step is critical because:
The storage system is heavy and tall, creating a tip-over risk.
Anchored racks improve stability during maintenance (when components are extended).
It protects equipment from accidental movement or vibration.
Many data center safety standards require rack anchoring before installation.
NEW QUESTION # 19
Which three RAID Group configurations are supported on a VSP 5000 system? (Choose three.)
- A. RAID6 (6D+2P)
- B. RAID6 (7D+2P)
- C. RAID5 (7D+1P)
- D. RAID5 (4D+1P)
- E. RAID1 (2D+2D)
Answer: B,D,E
Explanation:
RAID1 (2D+2D)
RAID1 (2D+2D) is a supported RAID1 configuration providing mirroring for high availability.
RAID5 (4D+1P)
RAID5 (4D+1P) is a commonly supported RAID5 layout with four data drives and one parity drive.
RAID6 (7D+2P)
RAID6 (7D+2P) is a supported RAID6 configuration, offering double parity and improved fault tolerance.
NEW QUESTION # 20
To perform configuration changes on VSP 5000 systems without affecting data availability, the changes must be:
- A. Scheduled during system downtime
- B. Performed manually by a technician
- C. Approved by the system administrator
- D. Executed online with appropriate planning
Answer: D
Explanation:
The Hitachi VSP 5000 is designed for high availability and supports online configuration changes.
This allows administrators to:
Modify RAID groups, volumes, or storage pools
Update network or host assignments
Perform maintenance tasks
...without taking the system offline, as long as the changes are carefully planned to avoid disrupting active data paths.
NEW QUESTION # 21
A disk drive is in failed state in a VSP 5600 system and you want to replace it. Which two actions should you perform as part of the replacement procedure? (Choose two.)
- A. Initiate the Correction Copy process.
- B. Activate Dynamic Sparing.
- C. Block the drive with the Maintenance Utility.
- D. Replace the drive.
Answer: C,D
Explanation:
Replace the drive.
Physically replacing the failed drive is a required step in the drive replacement procedure.
Block the drive with the Maintenance Utility.
Before removal, the failed drive should be logically blocked using the Maintenance Utility to safely isolate it from the system and prevent I/O errors during replacement.
NEW QUESTION # 22
A customer wants to upgrade a VSP 5500 to a VSP 5600. Which two actions are required for this upgrade? (Choose two.)
- A. Replace all the Power Supplies with more powerful ones.
- B. Replace all the controller boards.
- C. Replace all the memory DIMMs.
- D. Replace the CPUs on all the controller boards.
Answer: A,B
Explanation:
Replace all the controller boards.
Upgrading from VSP 5500 to VSP 5600 requires installing new controller boards, as the 5600 uses a different and more advanced controller architecture.
Replace all the Power Supplies with more powerful ones.
The upgrade also requires replacing the power supplies with models that are compatible with and can support the power requirements of the VSP 5600 controllers.
NEW QUESTION # 23
Which two statements are true about the spare drive in a VSP 5000 system? (Choose two.)
- A. The customer can decide which slot is to be used for the spare drive.
- B. Only slot 11 and slot 23 of DBS2 can be used as spare.
- C. If one of the slot 11 of the SBX is used as spare, the 3 remaining slots 11 could only be used as spare.
- D. The VSP 5000 system will allocate a spare slot automatically if "Spare slot allocation" is set to
"Variable" at installation time.
Answer: A,D
Explanation:
The customer can decide which slot is to be used for the spare drive.
With "Fixed" spare slot allocation, the customer has the flexibility to select which drive slot will serve as the spare during system configuration.
The VSP 5000 system will allocate a spare slot automatically if "Spare slot allocation" is set to
"Variable" at installation time.
If the "Variable" option is chosen for spare slot allocation, the system automatically selects and assigns spare drive locations.
NEW QUESTION # 24
Which tool do you use to configure SNMP on a VSP 5000 storage system?
- A. Maintenance Utility
- B. Webconsole
- C. SVP application
- D. Maintenance Utility Sub Panel
Answer: C
Explanation:
The SVP (Service Processor) application is used to configure SNMP settings on a VSP 5000 storage system. This tool provides access to system management features, including SNMP configuration.
NEW QUESTION # 25
You are installing a VSP 5500h with 3 pairs of CBXs. What is the total number of X-PATH cables that will be attached to the ISW ports?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
Explanation:
A VSP 5500h system with 3 pairs of Controller Boxes (CBXs) requires a total of 48 X-PATH cables attached to the Interconnect Switch (ISW) ports. Each CBX pair contributes 16 X-PATH cables (8 per CBX), and with 3 pairs, the total is 3 × 16 = 48.
NEW QUESTION # 26
How do you validate the network settings configuration on a newly installed VSP 5000 storage system?
- A. By performing a system reboot
- B. Using an external network configuration audit tool
- C. By disconnecting and reconnecting the network cables
- D. Through the management console's network test function
Answer: D
Explanation:
The Hitachi VSP 5000 storage system provides a built-in management interface that allows administrators to verify configuration settings after installation.
Using the management console network test tools, administrators can:
Validate IP configuration
Check network connectivity
Verify gateway and DNS settings
Test communication with management hosts or monitoring systems
These built-in diagnostic functions help ensure that the network configuration is correct and operational before the system goes into production.
NEW QUESTION # 27
What are the key benefits of correctly performing a "New Installation" procedure for VSP 5000 storage systems? (Choose Three)
- A. Extended hardware lifespan
- B. Increased storage capacity
- C. Optimal system performance
- D. Enhanced system security
- E. Reduced risk of installation-related issues
Answer: C,D,E
Explanation:
Performing a proper new installation procedure for the Hitachi VSP 5000 ensures that the system is set up correctly and ready for reliable operation. Key benefits include:
Optimal system performance (B)
Correct configuration of storage controllers, network connections, and RAID groups ensures efficient I/O handling and system throughput.
Enhanced system security (C)
Properly configuring access controls, user permissions, and network settings helps protect data and prevent unauthorized access.
Reduced risk of installation-related issues (D)
Following the recommended steps minimizes errors such as connectivity problems, misconfigured storage, or hardware misalignment, which could lead to downtime.
NEW QUESTION # 28
Which two part replacements in a VSP 5000 system require blocking the controller? (Choose two.)
- A. Hitachi Interconnect Edge (HIE)
- B. Cache Flash Module (CFM)
- C. Controller PCB
- D. Cache DIMM
Answer: C,D
Explanation:
Controller PCB
Replacing the Controller PCB requires blocking the controller to ensure system integrity and prevent data loss during the hardware change.
Cache DIMM
Cache DIMMs are part of the controller's critical memory subsystem, so the controller must be blocked before replacing any cache DIMMs to avoid corruption and ensure a safe replacement process.
NEW QUESTION # 29
You are installing a new VSP 5500 storage system. Which tool is used to install the initial license keys?
- A. Maintenance Utility
- B. Webconsole
- C. Storage Navigator
- D. SVP application
Answer: C
Explanation:
Storage Navigator is the tool used to install the initial license keys on a new VSP 5500 storage system. It provides the necessary interface for license management and activation.
NEW QUESTION # 30
Which component in the VSP 5000 series is responsible for managing front-end connectivity?
- A. Disk Adapter (DKA)
- B. Cache Memory
- C. Channel Board (CHB)
- D. Data Accelerator
Answer: C
Explanation:
In the Hitachi VSP 5000 storage system:
The Channel Board (CHB) is responsible for front-end connectivity, meaning it manages the communication between the storage system and hosts or servers over interfaces like Fibre Channel or iSCSI.
It handles I/O requests, protocol processing, and ensures data flows correctly between external hosts and internal storage components.
NEW QUESTION # 31
When installing a VSP 5000, it's essential to properly plan the __________ to avoid future connectivity issues.
- A. power distribution
- B. cable management
- C. network configuration
- D. cooling paths
Answer: C
Explanation:
During installation of the Hitachi VSP 5000 enterprise storage system, network configuration planning is essential to ensure proper communication between the storage array and other components in the IT infrastructure.
Key elements of network configuration include:
Assigning IP addresses for management interfaces
Configuring VLANs and subnets
Planning SAN connectivity (Fibre Channel / Ethernet)
Setting up redundant network paths
Ensuring compatibility with existing switches and hosts
Proper planning prevents common connectivity problems such as:
host access failures
misrouted traffic
management interface inaccessibility.
NEW QUESTION # 32
How many Channel Boards (CHBs) can be installed in a VSP 5600 with two CBX?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
Explanation:
In a VSP 5600 system configured with two Controller Boxes (CBXs), you can install up to 16 Channel Boards (CHBs) in total. Each CBX can accommodate up to 8 CHBs, resulting in a combined maximum of 16 CHBs for the system. This configuration allows for scalable host connectivity options, supporting various protocols such as Fibre Channel, iSCSI, and FICON.
NEW QUESTION # 33
......